To ask our experts a question aboutsensorsplease include your contact details. Call us toll free Our Member Store gives you access to the following advantages:. Some of our pricing is already discounted.
Cart 0 My Quote 0. Data Loggers Thermo-Hygrometers Thermometers. Emission Leak. The testo also has numerous diagnosis functions with easy-to-understand readings and information. The exhaust gas analyzer constantly displays the current reading.
The Analysis Box can be controlled by the Control Unit. After the Analysis Box has been programmed, it can carry out measurements independently and save the results. It can also transfer the data directly to the Control Unit. Conducting industrial emission measurements with the testo The testo exhaust gas analyser has been specially designed for carrying out industrial emission measurements in the field. Please note: The testo analyzer unit can only be used in combination with the testo Control Unit or the "easyEmission" software.
These items are available separately. Probes Flue gas probes. Order Number: Pitot tubes. Temperature probes. Combustion air temperature probe, immersion depth 60 mm Order Number: Accessories Accessories. The Control Unit complements the testo Analysis Box separate product and makes it easier to control emission measurements.
Transport case Order Number: Applications Service measurement on gas turbines Gas turbines are subject to flue gas limit values which are to be adhered to during operation and regularly checked depending on the size of the system.
Service measurement on gas turbines Gas turbines are subject to flue gas limit values which are to be adhered to during operation and regularly checked depending on the size of the system. Service measurement on industrial engines The flue exhaust gas analyzer testo is an important tool for adjusting a gas or diesel engine to optimum effect.
Analysis of the gas atmosphere thermal processes The flue gas analysis is used for thermal process monitoring in process combustion systems, such as in continuous furnaces for the glass, ceramics and construction material sector, or in steel melting and hardening furnaces, etc. In processes of this kind, substances may pass from the product being processed into the flue gas, increasing the usual emissions produced by the combustion system; vice versa, pollutants may pass from the gas and become part of the product being processed.
Pitot tube, stainless steel, Pitot tube, stainless steel, 3. Temperature probes. Combustion air temperature probe, immersion depth 60 mm Order Number: Type K NiCr-Ni probes. Sets Sets.
Accessories Accessories. Transport case for secure and tidy storage of testo flue gas analyzer, flue gas probe and accessories, dimensions x x mm LxWxH Order Number: Carrying belt kit for analyzer box and control unit Order Number: Cable with battery clamps and adapter for connection to DC Input of testo analyzer box Order Number: Spare particle filter, pack of 20 Order Number: NO replacement filter, 1 off Order Number: Printer and accessories.
Compact printer, with IRDA technology offers fast, easy to read printouts of measurements at every job site. Internal magnets will hold the printer to magnetic surfaces for hands free operation.
Spare thermal paper, permanent ink Order Number: Connection cable for Testo databus between Control Unit and analyzer box or between several analyzer boxes, with bayonet connection, length 2 m. Connection cable for Testo databus between Control Unit and analyzer box or between several analyzer boxes, with bayonet fitting, length 5 m Order Number: Set Analog output box, 6 channels, 4 to 20 mA, for output of the measurement values on for example an analog recorder, set consists of analog output box, connection cable Testo databus, length 2 m, Testo databus terminal plug Order Number: Software "easyEmission" for testo , incl.
Applications Better combustion testing and tuning Sometimes a single sample location is just not enough for an optimum measurement. Better combustion testing and tuning Sometimes a single sample location is just not enough for an optimum measurement.
Better Engine Testing Analyzer requirements for emission and combustion analysis can vary based on the different combustion applications. Measures both NO and NO2 for proper engine set up and unsurpassed accuracy. Analysis of the gas atmosphere thermal processes The flue gas analysis is used for thermal process monitoring in process combustion systems, such as in continuous furnaces for the glass, ceramics and construction material sector, or in steel melting and hardening furnaces, etc.
In processes of this kind, substances may pass from the product being processed into the flue gas, increasing the usual emissions produced by the combustion system; vice versa, pollutants may pass from the gas and become part of the product being processed.
Better Industrial Testing Combustion analyses in industrial processes vary widely. If the home has an attached garage, document CO levels in garage. Accept this level as normal for unvented appliances but not for vented appliances. If unvented appliances are in operation, recommend additional ventilation in the areas of operation. With ambient conditions in this range, analysts may continue testing to locate the CO source.
Conditions must be mitigated. Actions: Ask occupants to step outside and query about health symptoms. Advise occupants to seek medical attention. If occupants exhibit any symptoms of CO poisoning, have someone drive them to a medical facility.
Enter the building, open doors and windows to ventilate the structure.